  • BL-30N-485/BL-30NZ-485

    BL-30N-485/BL-30NZ-485

    Laser displacement sensor

    Model BL-30N-485/BL-30NZ-485 Output type NPN+485 Communication output Measurement center Distance 30mm Measurement range ±5mm Repeatability 10um straightness ±0.1%F.S Temperature characteristic 0.03%F.S./℃ Beam diameter about φ50um Protection Circuit power polarity reverse protection, Output short circuit or overload protection Environmental brightness incandescent lamp: the illuminated surface is less than 3000lx power supply voltage 12-24VDC±10%, floating P-P10% power consumption current less than 40mA (when the power supply voltage is 24VDC) less than 60mA

  • BLP-M40-485

    BLP-M40-485

    Laser displacement sensor

    Model BLP-M40-485 Output type NPN+485 Output Measurement distance 40m Linear accuracy ±(1.5mm+0.05%F.S.) Resolution 1mm data output rate Single measurement: 100ms; Continuous measurement: 30-100ms light source medium: red diode laser, 630-670nm Output power: < 1mW laser grade: IECclass2 startup time < 3s operating voltage 12~26VDC operating current < 44mA Maximum current 65mA ambient illumination incandescent lamp ≤3000Lux; too

  • BLG-120N-485

    BLG-120N-485

    Laser displacement sensor

    Model BLG-120N-485 Output type NPN+485 Output Measurement Center Distance 120mm Measurement range 120mm Linear accuracy ±0.1%F.S.(F.S.=120mm) Resolution 30um (4W in fast mode) Temperature drift characteristic ±0.08%F.S./°C Response time Fast mode: max.5ms: Average sampling times 1 (1ms) + Sensitivity switching time (max.4ms) Standard mode: max.12.5mss Average sampling times 16 (8.5ms) + sensitivity switching time (max.4)

  • BLG-120NM

    BLG-120NM

    Laser displacement sensor

    Model BLG-120NM Output Type NPN+ Analog Output Measurement Center Distance 120mm Measurement range 120mm Linear accuracy ±0.1%F.S.(F.S.=120mm) Resolution 30um (4W in fast mode) Temperature drift characteristic ±0.08%F.S./°C Response time Fast mode: max.5ms: Average sampling times 1 (1ms) + Sensitivity switching time (max.4ms) Standard mode: max.12.5mss Average sampling times 16 (8.5ms) + Sensitivity switching time (max.4ms)

  • BLG-50N-485

    BLG-50N-485

    Laser displacement sensor

    Model BLG-50N-485 Output Type NPN+485 Output Measurement Center Distance 50mm Measurement range 20mm Linear accuracy ±0.1%F.S.(F.S.=20mm) Resolution 5um (4W in fast mode) Temperature drift characteristic ±0.08%F.S./°C Response time Fast mode: max.5ms: Average sampling times 1 (1ms) + Sensitivity switching time (max.4ms) Standard mode: max.12.5mss Average sampling times 16 (8.5ms) + Sensitivity switching time (max.4ms) High

  • BLG-50NM

    BLG-50NM

    Laser displacement sensor

    Model BLG-50NM Output Type NPN+ Analog Output Measurement Center Distance 50mm Measurement range 20mm Linear accuracy ±0.1%F.S.(F.S.=20mm) Resolution 5um (4W in fast mode) Temperature drift characteristic ±0.08%F.S./°C Response time Fast mode: max.5ms: Average sampling times 1 (1ms) + Sensitivity switching time (max.4ms) Standard mode: max.12.5mss Average sampling times 16 (8.5ms) + Sensitivity switching time (max.4ms) High mode:

  • BL-200N-485/BL-200NZ-485

    BL-200N-485/BL-200NZ-485

    Laser displacement sensor

    Model BL-200N-485/BL-200NZ-485 Output type NPN+485 Communication output Measurement Center Distance 200mm Measurement range ±80mm Repeatability 200um linearity ±0.2%F.S Temperature characteristic 0.03%F.S./℃ Beam diameter about φ300um protection Circuit power polarity reverse protection, Output short circuit or overload protection Environmental brightness incandescent lamp: illuminated surface lighting degree below 3000lx power supply voltage 12-24VDC±10%, floating P-P10% power consumption current below 40mA (power supply voltage 24VDC)

  • BL-200NM/BL-200NMZ

    BL-200NM/BL-200NMZ

    Laser displacement sensor

    Model BL-200NM/BL-200NMZ Output type NPN+ Analog Output Measurement Center distance 200mm Measurement range ±80mm Repeatability 200um linearity ±0.2%F.S Temperature characteristic 0.03%F.S./℃ Beam diameter about φ300um protection Circuit power polarity reverse protection, Output short circuit or overload protection Environmental brightness incandescent lamp: the illuminated surface is less than 3000lx power supply voltage 12-24VDC±10%, floating P-P10% power consumption current less than 40mA (power supply voltage 24VDC) less than 60mA (electricity

  • BL-200N/BL-200NZ

    BL-200N/BL-200NZ

    Laser displacement sensor

    Model BL-200N/BL-200NZ Output type NPN Output Measurement center Distance 200mm Measurement range ±80mm Repeatability 200um linearity ±0.2%F.S Temperature characteristic 0.03%F.S./℃ Beam diameter about φ300um protection Circuit power polarity reverse protection, Output short-circuit or overload protection Environmental brightness incandescent lamp: the illuminated surface is less than 3000lx power supply voltage 12-24VDC±10%, floating P-P10% power consumption current less than 40mA (when the power supply voltage is 24VDC) less than 60mA (voltage voltage 12V)